Cart 0

Single Beam UV VIS Spectrophotometer TRSUV-605is a small device with a 7-inch multi-color touch screen. It has an automatic wavelength range of 190 to 1100 nm as well as a bandwidth of 2 nm. Having patented technology that allows for simple and effective human-computer interaction with a clear display of test data It has a photometric range of 0.0 to 200.0 % T, -0.301 to 4.000A, and 0.000 to 9999 C with an accuracy of 0.3 % T, 0.002Abs (0 to 0.5A) and 0.004Abs (0 to 9999 C) (0.5 to 1A). It includes a sample compartment for 5 to 50 mm cuvettes. Delivered with a wavelength scanning Speed.

$1,586.00
  

Qty:

  
Specifications
Photometry Single Beam
Monochromatic Type Czerny-Turner
Focal Length 160 mm
Grating 1200 lines/mm
Detector Silicon Photocell
Spectrum Bandwidth 2nm
Wavelength Range 190 to 1100 nm
Wavelength Accuracy ± 1 nm
Wavelength Repeatability ≤ 0.5 nm
Photometric Range 0.0 to 200.0% T, -0.301 to 4.000A, 0.000 to 9999C
Photometric Accuracy ± 0.3% T, ± 0.002Abs (0 to 0.5 A)± 0.004Abs (0.5 to 1 A)
Photometric Repeatability ≤ 0.15% T, 0.001Abs (0 to 0.5 A)0.002Abs (0.5 to 1 A)
Wavelength Scanning Speed Fast, medium, slow
Baseline Flatness ≤ ± 0.003 A(200 to 1090 nm)
Stray Light ≤ 0.1% ( at 220 nm NaI ; at 360 nm NaNO2)
Noise 100%(T) noise ≤ 0.5% (T), 0% (T) noise ≤ 0.2% (T)
Baseline Drift ± 0.002 Abs / 30 mins (250 nm and 500 nm after preheating warm-up for 2 hours )
Power AC220 V ± 22 V, 50Hz ± 1Hz, 180 W
Packing Size 630 mm×610 mm×500 mm
Weight 0.16m³, 25 Kg
Features
  • 7-inch multi-color touch screen and patented technology for simple and effective human-computer interaction with clear test data display
  • A built-in thermal printer for printing test results and facilitating the creation and storage of data reports
  • A USB communication port and UV professional data processing software enables data processing and mapping functions
  • The storage of large amounts of data files, and help customers with a second development
  • Sample compartment for 5 to 50mm cuvettes
  • Automatic wavelength selection, which is both quick and accurate
  • Scanning kinetic time scanning, automatic wavelength, linear regression, direct concentration readout, peak detection, regular printing, and so on
  • Power shutdown protection measures that are advanced to memorize detector data and regression
  • To achieve fast initialization, the equation and instrument correction parameters must be known ahead of time
  • Lifelong safety for tungsten and deuterium lamps
Standard Accessories
  • Accessories NoName
    11 cm glass cuvettes
    2Output Port USB Port & RS232 Port
    3UV- ANALYST software
Optional Accessories
  • Accessories NoName
    1Mini Serial Printe
Application

It is an ideal instrument which is widely used in Research laboratories, Research Organizations or Institutes for educational purpose, QC laboratories.

Frequently Asked Questions

Yes, we offer a range of rotors compatible with their centrifuge models, including, Fixed-Angle Rotors, Swing-Bucket Rotors, Microplate Rotors and Specialized Rotors.

The digital display allows users to monitor current speed and remaining time, providing precise control over the centrifugation process.?

Absolutely. Its compact design, quiet operation, and safety features make it ideal for clinical laboratories, research institutions, and educational settings.

It's advisable to clean the centrifuge after each use, inspect the rotor and lid regularly for signs of wear, and ensure the device is calibrated periodically to maintain accuracy. ?

Yes, this models allow for real-time adjustments of speed and time without interrupting the ongoing process. This feature provides flexibility to accommodate protocol changes on the fly.

Absolutely! Once your order is shipped, you will receive an email with a tracking number and link. Simply click the link to track your package in real-time.

Yes, we offer free standard shipping on orders over a certain amount. The minimum order amount for free shipping may vary, so please check our Shipping Policy page for the most up-to-date information.

We accept a variety of payment methods to make your shopping experience easy and convenient. These include major credit and debit cards (Visa, MasterCard, American Express), PayPal, Apple Pay, Google Pay, and others. You can view all available options at checkout.

Related Models Of Single Beam UV VIS Spectrophotometer

Single Beam UV-Visible Spectrophotometers are designed for accurate measurement of light absorbance and transmittance. They provide a wide wavelength range, covering the UV and visible spectrum for diverse applications. These units include automatic wavelength adjustment, ensuring precise and consistent wavelength selection. Our Spectrophotometers retain data after power loss, ensuring secure results. They provide USB and printer connectivity, allowing easy data transfer and efficient reporting.

  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
$1,799.00
  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
$1,913.00
  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
$1,170.00
  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
$1,218.00
  • Photometry : Split Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
$1,359.00
  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
$1,082.00
  • Photometry : Single Beam
  • Monochromatic Type : Czerny-Turner
  • Focal Length : 160 mm
$1,169.00

  • Wavelength Range : 190 to 900 nm
  • Wavelength Accuracy : £ ±0.5 nm
  • Wavelength Repeatability : £ 0.3 nm (single direction)
$1,980.00
  • Wavelength range  : 190 to 900 nm
  • Spectral bandwidth : 0.1, 0.2, 0.4, 1.0 and 2.0 nm
  • Accuracy of the wavelength : ±0.15 nm
$1,536.00
  • Wavelength Range : 190 to 850 nm
  • Wavelength Accuracy : ± 1 nm
  • Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
$1,922.00
  • Wavelength Range : 190 to 850 nm
  • Wavelength Accuracy : ± 1nm
  • Wavelength Resolution : 2 nm (FWHM at Hg 546 nm)
$1,329.00
  • Light Path : 1mm
  • sample Volume : 1 to 2μL
  • Detection Range : 190 to 850 nm
$1,963.00
  • Optical Path : 1/0.5/0.05 mm automatic conversion
  • Optical Range : 190 to 1100 nm
  • Sample Volume : 0.3 to 2.0 μl
$1,334.00
  • Analysis Principle : Energy-dispersive X-ray fluorescence analysis
  • Element Measuring Range : Any element from Na(11)-U(92)
  • Minimum Measuring Limit : Cd/Hg/Br/Cr/Pb≤2 ppm
$1,537.00
  • Exciting Optical Filters : Interface optical filter (10 nm bandwidth)
  • Wavelength : 365 nm
  • Emission Monochromatic : C-T diffraction grating (EM 200 to 900 nm )
$1,066.00
  • Spectrum Bandwidth : 2 nm
  • Wavelength Range : 190 to 1100 nm
  • Monochromatic Type : Czerny-Turner
$1,665.00
  • Spectrum Bandwidth : 0.5 nm, 1nm, 2 nm, 4 nm, 5 nm
  • Wavelength Range : 190 to 1100 nm
  • Monochromatic Type : Czerny-Turner
$1,573.00
  • Monochromatic type : Czerny turner
  • Focal length : 160 mm
  • Wavelength Range : 190 to 1100 nm
$1,906.00
  • Monochromatic type : Czerny turner
  • Focal length : 160 mm
  • Wavelength Range : 190 to 1100nm
$1,833.00
  • Photometry : Single beam
  • Monochromatic Type : Littrow
  • Focal Length : 160 mm
$1,186.00